The tension Dead-end for ADSS is intended for turning angle, continuing and terminal connecting. The helical aluminum clad steel rod has strong tensile strength, no concentrated stress, plays a role to protect cable and assist reducing vibration.
  • item no.:

    ANY-XXXX
  • lead time:

    30 days after receiving deposit
  • product orgin:

    China
  • shipping port:

    Shenzhen
  • payment:

    T/T
  • product details
Product Instruction:

Tension Dead end for ADSS is intended to turn angle, continue, and connect terminal. Helical aluminum clad steel rod, with great tensile strength and no concentrated stress, may play a role to protect cable and assist reducing vibration. The whole set of cable tension hardware contains: outer structural reinforcing rod (dead end), structural reinforcing rod, and matching connection hardware. Clamp holding strength is no less than 95% of rated tensile strength, easy and quick to install, reduce construction cost.

 

Function:

The hardware is mainly intended to bear axial stress and distribute uniformly radial stress, so as to offer a safe and reliable holding strength on the premise of not damaging cable (mostly used in turning angle, continuing pole and terminal pole).

 

Parameter:

Configure model by cable diameter, RTS.

 

Installation of Tension Dead-end for Medium Span ADSS
 
Components: outer structural reinforcing rod (dead end), structural reinforcing rod, anchor shackle, extension link, thimble clevis, ground wire Components: anchor shackle, chain link, thimble clevis, outer structural reinforcing rod (dead-end), structural reinforcing rod
  
Installation Steps:

1.   Assemble anchor shackle, extension link, and thimble clevis together;1.   Assemble Anchor shackle, chain link and thimble clevis together;

2.   Fix Anchor shackle at a hanging point;

3.   Pull one leg of outer structural reinforcing rod (dead end) through thimble clevis, and connect it, make both legs of outer structural reinforcing rod (dead end) paralleled with cable, and make a crossover mark on cable according to installation color mark of outer preformed rod (dead end); 

4.   Make the structural reinforcing rod’s end color mark aligned to the crossover mark made in step;
 
5.   Align the center color mark of the 2nd structural reinforcing rod, and wind onto cable levelly for about 2 pitches without overlap;
 
6.   As former step, wind 3rd and 4th structural reinforcing rods onto cable levelly for about 2 pitches without overlap; 

7.   For convenience, tear the part of about 20-30cm from the end of structural reinforcing rod into smaller subsets winding;

8.   Wind its end levelly by hand (not use tool to prevent from damaging cable);
 
9.   Make the two color marks of outer structural reinforcing rod (dead end) and structural reinforcing rod aligned, wind one leg of outer structural reinforcing rod (dead end) for 2-3 pitches;

10.   As former step, wind another leg for 2-3 pitches in the same way, while wind the outer structural reinforcing rod (dead end) until the place of about 20-30cm from the end;
 
11.   For convenience, tear the part of about 20-30cm from the end of outer structural reinforcing rod (dead end) into smaller subsets winding; 
 
12.   Installation is over.
 
 
Instructions:
 
1.   Select the tension clamp model according to cable outer diameter, rated tensile strength (or span), etc;
2.   To prevent from extrusion, severe impact and deformation in its moving and installation;  
3.   As matching parts, tension clamp shan’t be changed randomly, and not be used repeatedly, It may be disassembled and assembled just once, which is a permanent installation, shan’t be disassembled once again;  
4.   To wind the structural reinforcing rod, it’s required to operated by hand, not use any tool to avoid from damaging cable;
5.   If in doubt, please contact us.


Request a free quote
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
related products
OPGW tension dead-end clamp

Guy Grip Dead End Tension Clamp Assembly for OPGW cable accessories

Tension Dead end or Guy Grip setfor OPGW is intended to turn angle, continue, and connect terminal. Helical aluminum clad steel rod, with great tensile strength and no concentrated stress, may play a role to protect cable and assist reducing vibration.

Vibration Damper

Vibration Damper (Hammer) / Aluminum Alloy

Poduct material: 1.Aluminum alloy Anodized aluminum hardware 2.Function: It is commonly used in OPGW cable anti-vibration device and also ADSS    cable. 3.Parameter: Configure model by cabl Used to e diameter, RTS and unit weight

vibration damper

Cable Vibration Damper/Searhorse-type

it is commonly used in OPGW cable anti-vibration device and also ADSS cable to prevent fatigue damage from wind-induced aeolian vibration.

Suspension Set

Suspension Set for ADSS Cable/Aluminum Alloy Wire

Material for helical reinforced rods - aluminum alloy wire. Rubber liner - ternary rubber.

clamp

Leading down Clamp/Prevent the Cable from Shaking

it is usually used to fix cable to avoid shaking. Leading down or upward to fix the cable to cable connecting tower, middle tension tower and terminal tower.

Suspension Clamp (SOCLS)

OPGW Cable Double Suspension Clamp (SOCLS)

The suspension clamp for OPGW is mainly used to hang OPGW cable on the transmission line support and connect immediate support to angle 25°-50°. Each support match one set.

 
chat now please click here for inquiry
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!