   Tension Dead end for OPGW is intended to turn angle, continue, and connect terminal. Helical aluminum clad steel rod, with great tensile strength and no concentrated stress, may play a role to protect cable and assist reducing vibration.
  • item no.:

    ONY-XXXX
  • lead time:

    30 days after receiving deposit
  • product orgin:

    China
  • shipping port:

    Shenzhen
  • payment:

    T/T
  • product details
Product Instruction:

Tension Dead end for OPGW  is intended to turn angle, continue, and connect terminal. Helical aluminum clad steel rod, with great tensile strength and no concentrated stress, may play a role to protect cable and assist reducing vibration. The whole set of cable tension hardware contains: outer structural reinforcing rod (dead end), structural reinforcing rod, and matching connection hardware. Clamp holding strength is no less than 95% of rated tensile strength, easy and quick to install, reduce construction cost.

 

Function:

The hardware is mainly intended to bear axial stress and distribute uniformly radial stress, so as to offer a safe and reliable holding strength on the premise of not damaging cable (mostly used in turning angle, continuing pole and terminal pole).

 

Parameter:

Configure model by cable diameter, RTS.

 

Installation of Tension Dead End for OPGW
 
Components: outer structural reinforcing rod (dead end), structural reinforcing rod, anchor shackle, extension link, thimble clevis, ground wire 
 
 Picture of Tension Dead-end for OPGW installation,product functions and application
  
Installation Steps:

1.   Assemble anchor shackle, extension link, and thimble clevis together;
 
2.   Fix anchor shackle at a hang point;
 
3.   Insert one leg of outer structural reinforcingrod (dead end) into thimble clevis;

4.   Parallel cable with both legs of the outer structural reinforcingrod (dead end), make a crossover mark on cable according to installation color mark on the outer structural reinforcing rod (dead end);
 
5.   Make the end color mark of structural reinforcing rod aligned with the crossover mark made in step 4, leaving its short-end toward iron tower, wind structural reinforcing rod about 2 pitches beginning from installation mark;
 
6.   Align the center color mark of the 2nd structural reinforcing rod, and wind onto cable for about 2 pitches levelly without overlap;

7.   As former step, wind the 3rd and 4th sets of structural reinforcing rod onto cable levelly for about 2 pitches without overlap;
 
8.   For convenience, tear the 20-30cm part from the end of structural reinforcing rod into smaller subsets winding;
 
9.   Wind its end levelly by hand (not use any tools to avoid from damaging cable);
 
10.   Align the two color marks of outer structural reinforcing rod (dead end) and structural reinforcing rod, wind one leg of outer structural reinforcing rod (dead end) for 1-2 pitches;

11.   As former step, wind another end of structural reinforcing rod for 2-3 pitches in the same way, and then wind the outer structural reinforcing rod (dead end) until 20-30cm from the end of structural reinforcing rod;
 
12.   For convenience, tear the 20-30cm part from the end of structural reinforcing rod into smaller subsets winding;

13.   Connect the pliers-clamp of ground wire, screw up;

14.   Wear with ground terminal, lock nut up;

15.   Installation is over.
 
 
Instructions:
 
1.   Select the tension clamp model according to cable outer diameter, rated tensile strength (or span), etc;
2.   To prevent from extrusion, severe impact and deformation in its moving and installation;  
3.   As matching parts, tension clamp shan’t be changed randomly, and not be used repeatedly, It may be disassembled and assembled just once, which is a permanent installation, shan’t be disassembled once again;  
4.   To wind the structural reinforcing rod, it’s required to operated by hand, not use any tool to avoid from damaging cable;
5.   If in doubt, please contact us.


Request a free quote
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!
related products
ADSS OPGW Vibration Damper

Stockbridge Vibration Damper for ADSS OPGW cable

Vibration Damper used in OPGW cable anti-vibration device and also ADSS cable.

Helical Insulator Distribution Tie

Distribution Tie for use on ACSR, Aluminum Alloy

Suitable for bare wires and insulated wires

Suspension Set

Suspension Set for ADSS Cable/Aluminum Alloy Wire

Material for preformed reinforced rods - aluminum alloy wire. Rubber liner - ternary rubber.

Helical Insulator Distribution Tie

Distribution Tie for use on ACSR, Aluminum Alloy

Suitable for bare wires and insulated wires

Joint Box

Cap-type plastic Joint Box /Splicing of ADSS and OPGW Fiber/96 Core

Cap-type palstic Joint Box:used for splicing of ADSS and OPGW fiber.The maximum capacity is 96 core.

Metal Dome Splice Closure

Metal Dome Fiber Optic Splice Closure Outdoor cable joint box 24 core 36 fiber

24 core 36 fiber Fiber Optic Splice Closure,for OPGW and ADSS fiber optic cable connections

 
chat now please click here for inquiry
If you have questions or suggestions,please leave us a message,we will reply you as soon as we can!